Home    HVAC  KANE 255 infra-rood rookgasanalyser
KANE 255 infra-rood rookgasanalyser

KANE 255 infra-rood rookgasanalyser


IR-CO2, CO,O2, CO/CO2, ppm, °C, ...

  • Sensors : CO long life (>5 years) & CO2 infrared (>5 years)
  • Multi-fuel: Natural Gas, Propane, Butane, LPG, Light Oils (28/35 sec), and Wood Pellets
  • Self-test : standard, results are indicated on the display
  • Calibration : automatic with starting the instrument
  • Measuring conditions : 0°...+600°C


EUR 980.00
excl. BTW

Artikelcode: 271-0255

KANE 255 infra-rood rookgasanalyser


  • Productinformatie
  • Gelerateerde producten

The KANE255 Combustion Analyser measures carbon dioxide (CO2), carbon monoxide (CO) and Flue temperature. It calculates oxygen (O2), CO/CO2, ratio, losses, combustion efficiency (Nett, Gross or Condensing) and excess air.

In addition the KANE255 Combustion Analyser’s CO sensor checks CO levels in ambient air – useful when a CO Alarm is triggered. The CO reading can be referenced to the oxygen reading in ppm or mg/m3.

  • Dispay : LCD display 62 x 52 mm with backlight
  • Built-in flashlight with LED
  • Sensors : CO long life (> 5 years) & CO2 infrared (> 5 years)
  • Fuel types : natural gas, LPG, propane, butane, light oil, wood pellets
  • Self diagnosis : standard, results appear on the screen
  • Calibration : automatic when switching on the instrument
  • Printer : external, infrared
  • Roetindex measuring : via optional pump
  • Measuring temperature : 0°C to +600°C
  • Operating temperatur : 0°C to +40°C; 10-90% RH non-condensing
  • Power supply : 4 AA alcaline rechargeable batteries with charger
  • Battery life : >8 hours
  • Size : 200 x 45 x 90 mm
  • Weight : 1 kg (with rubber protection)
  • Probe : 300 x 6 mm with 200 mm thermocouple a d 3 m long neoprene hose

Measurements
- Oxygen : 0-21%
- Carbon monoxide : 0-2000 ppm(4000 ppm) or mg/m3
- Carbon dioxide : 0-20%
- Efficiency : 0-99,9%
- CO/CO2 ratio : 0-0,999
- Excess air : 0-250%
- Ambient operating range : 0°C...40°C
- Gas temperature : 0°C...+600°C
- Input temperature (external sensor) : 0°C...+600°C
- Pressure/differential rated : ± 80 mBar
- Maximum Pressure/differential : ± 400 mBar
- Air surplus : 0-250%

Storage capacity
- 20 sets of test results in volatile memory

Supplied with
- Protective rubber boot with magnet
- Analyser with CO2, CO
- Flue probe with integral temperature sensor
- Battery + charger
- Calibration certificate
- Instruction book
- Carrying case

Option
- Extra probes (air, liquid, surface temperature)
- Infrared printer